The VCS³7060-5 is a spacious climate stress chamber that is fully air-cooled, featuring heating and cooling rates that are higher than those of standard chambers.
Download specsheetThis unit offers a spacious test area with heating and cooling rates significantly higher compared to a standard climate chamber of the same size. The extra air-cooled condenser is connected to the machine via flexible hoses and is placed on a separate pallet, which needs to be situated near the climate chamber.
Despite its large volume and higher speeds, a 32A connection is still sufficient for this device. The wide temperature range of this unit ensures extra speed in heating up and cooling down and has the advantage of compensating for any additional power released in the test space. This device is suitable for simulating both constant conditions and for applying cyclically varying temperature or climate conditions.
Dimensions (W x D x H) |
800mm x 800mm x 950mm |
Transport dimensions (W x D x H) |
1087mm x 1910mm x 1998mm (machine) 1200mm x 1200mm x 1000mm (condenser) |
Volume | 600L |
Cable entry | Right 125mm, left 50mm diameter |
Cooling | Air-cooled |
Interface | Ethernet interface |
Electrical connection | 3P+N+PE 400Vac 32A |
Available options | Flat cable entry in door |
Temperature range | -72°C to +180°C |
Heating rate | 6,0K/min according to IEC 60068-3-5 |
Cooling rate | 6,0K/min according to IEC 60068-3-5 |
Maximum heat compensation | 5000W |
Temperature range | +10°C to +95°C |
Humidity range | 10% to 98% RH |
Dew point range | +4°C to +94°C / -3°C to +4°C discontinu |
Maximum heat compensation | 500W in the range of +25°C to +95°C at a relative humidity up to 90% RH |
On our website, we offer a selection from our assortment. Based on a conversation with our customers, we explore the possible options. It may also be a solution that we purchase your chosen option.